国产一区二区三精品久久久无广告,中文无码伦av中文字幕,久久99久久99精品免视看看,亚洲a∨无码精品色午夜

供配電設(shè)計論文范例6篇

前言:中文期刊網(wǎng)精心挑選了供配電設(shè)計論文范文供你參考和學(xué)習(xí),希望我們的參考范文能激發(fā)你的文章創(chuàng)作靈感,歡迎閱讀。

供配電設(shè)計論文

供配電設(shè)計論文范文1

1.1做好各個環(huán)節(jié)的的設(shè)計

要建設(shè)一套高質(zhì)量的配網(wǎng)系統(tǒng),首先要做的就是對系統(tǒng)的設(shè)計,萬事開頭難,設(shè)計環(huán)節(jié)也可以說是電力配網(wǎng)工程較難的環(huán)節(jié),一旦出現(xiàn)設(shè)計不合理或設(shè)計疏忽的問題,都會對后期配網(wǎng)工程系統(tǒng)的運營和維護造成一定的影響,因此,在保證配網(wǎng)工程系統(tǒng)設(shè)計合理性的同時,還要做好各個環(huán)節(jié)的設(shè)計工作。首先,要掌握220kv配網(wǎng)系統(tǒng)的組成,再根據(jù)地區(qū)、氣候等因素來對電力配網(wǎng)工程系統(tǒng)進行合理的設(shè)計,尤其是設(shè)計圖紙畫制,必須嚴格按照規(guī)范要求進行,這也是220kv配網(wǎng)工程系統(tǒng)設(shè)計過程中應(yīng)該注意的。其次,在220kv配網(wǎng)工程系統(tǒng)設(shè)計過程中,必須做好風(fēng)險預(yù)測和分析,尤其是對配網(wǎng)系統(tǒng)所在區(qū)域的地質(zhì)地貌、人文條件、自然氣候等因素的分析,有效的規(guī)避風(fēng)險因素,提高配網(wǎng)工程系統(tǒng)設(shè)計的有效性。再次,要加強系統(tǒng)設(shè)計過程中的監(jiān)督工作,在一定的時期下要對原有的監(jiān)督機制進行完善,進而提高220kv配電網(wǎng)后期運行的效率。

1.2在設(shè)計方案中對施工要求進行明確的規(guī)定

在設(shè)計方案中需要對施工的準備階段、施工階段、竣工驗收階段等三方面進行明確的規(guī)定,每個環(huán)節(jié)都必須嚴格按照配網(wǎng)工程系統(tǒng)設(shè)計方案進行,當(dāng)然,在必要的時候可以更改設(shè)計方案,但要盡量控制設(shè)計方案的變動,避免方案變動對系統(tǒng)施工以及運行造成影響。首先,要考慮的是220kv電力配網(wǎng)工程系統(tǒng)施工的準備階段,根據(jù)設(shè)計方案提供的機械設(shè)備、人員、材料、安全防護設(shè)施等方面的要求,做好前期的準備工作,為后期配網(wǎng)工程順利施工打下夯實的基礎(chǔ)。另外,要派專門的監(jiān)督人員,確保準備階段中的各項材料、設(shè)備、器械等質(zhì)量都滿足設(shè)計方案中的要求。其次,在施工階段,縱有質(zhì)量再好的材料和設(shè)備,如果施工階段出現(xiàn)問題的話,也會對工程質(zhì)量造成極大的影響,影響到配網(wǎng)系統(tǒng)的后期運行效率。因此,必須加強配網(wǎng)工程施工階段的安全管理,要求施工過程按照設(shè)計方案的要求實施。監(jiān)督管理人員與方案設(shè)計人員進行有效的溝通,了解配網(wǎng)工程系統(tǒng)的設(shè)計要點,再對每個施工環(huán)節(jié)進行監(jiān)督,確保每項環(huán)節(jié)都能滿足方案設(shè)計的質(zhì)量要求,并對每個施工環(huán)節(jié)的實際情況以及測試情況進行記錄,以便于對系統(tǒng)的優(yōu)化調(diào)整,這樣才能進一步確保電力配網(wǎng)工程系統(tǒng)設(shè)計的施工質(zhì)量,對配網(wǎng)系統(tǒng)后期的運行效率也非常有利。再次,要做好220kv電力配網(wǎng)工程系統(tǒng)竣工階段的工作,工程竣工檢驗合格之后就會投入到試運營階段,如果檢驗工作出現(xiàn)問題的話,勢必會造成配網(wǎng)系統(tǒng)的運行問題,會涉及到工程的維護費用,甚至?xí)霈F(xiàn)返工的現(xiàn)象,不僅延誤了配網(wǎng)系統(tǒng)投入運營的時間,還浪費了大量的人力、物力和財力,因此,在配網(wǎng)系統(tǒng)工程竣工檢驗期間,必須保證檢驗的質(zhì)量,避免系統(tǒng)投入運營再引發(fā)故障。為了提高配網(wǎng)系統(tǒng)工程的檢驗質(zhì)量,可以采取分段檢驗的方式,將各個系統(tǒng)分段區(qū)接入到總配網(wǎng)系統(tǒng)中測試,這樣可以確保每個區(qū)段的檢驗都能夠按照設(shè)計方案中的要求進行檢驗,一方面能夠?qū)ε渚W(wǎng)系統(tǒng)進行全面的檢驗,另一方面可以通過分段試運營的測試方式更好的對系統(tǒng)進行調(diào)整,從而節(jié)省大量的人力、物力和財力。

2總結(jié)

供配電設(shè)計論文范文2

【關(guān)鍵字】隧道,供配電,照明系統(tǒng),節(jié)能技術(shù),綜合應(yīng)用

中圖分類號:TE08 文獻標(biāo)識碼:A 文章編號:

一.前言

對不同省份的隧道管理部門的隨機調(diào)查中我們發(fā)現(xiàn),隧道供配電及照明系統(tǒng)所花費的電費已經(jīng)是公路隧道建設(shè)運營管理中最主要的開支。隧道的照明安全是不能忽視的,但是如何在保證隧道供配電及照明系統(tǒng)正常、安全運行的情況下減少電費的花費、降低隧道管理部門的成本投入,同時降低我國的電能消耗,已經(jīng)成為各個省市隧道管理部門共同面臨的難題,也是迫不及待要解決的問題。縱觀我國目前的隧道供配電及照明系統(tǒng)技術(shù),多數(shù)采用的是高功率因數(shù)的供配電和照明工具、合理安排配電房的位置、縮短供電電纜的長度、在隧道的兩側(cè)鋪設(shè)反射率較高的裝修材料等等。從這些所有使用的方法來看,雖然有些方法能起到較好的節(jié)能效果,但是從整體來看,仍然存在較高的電能浪費的情況。

目前國內(nèi)隧道供配電及照明技術(shù)的發(fā)展

我國隧道照明節(jié)能技術(shù)與國外先進水平相比,存在一定差距,主要表現(xiàn)在以下方面:

1、控制方式智能化水平低,未從不同的工況考慮不同的照明方案;

2、未考慮隧道照明顯色性與照度、亮度之間的關(guān)系 及光源的等效亮度、中間視覺、司辰視覺等新興視覺理論應(yīng)用于照明參數(shù)的研究;

3、未考慮照明系統(tǒng)的分期實施;

4、規(guī)范存在一定缺陷.現(xiàn)行規(guī)范忽略了對中、短隧道照明的論述;

5、隨著新型照明技術(shù)的迅速發(fā)展, 有必要研究其在隧道內(nèi)的應(yīng)用性,如LED燈、電磁感應(yīng)燈;

6、未系統(tǒng)性地考慮照明節(jié)能

三.我國隧道供配電及照明系統(tǒng)中節(jié)能技術(shù)的應(yīng)用現(xiàn)狀

1、隧道供電針對長大隧道供配電技術(shù)的專項研究較少,比如公路隧道供配電節(jié)能與管線優(yōu)化配置、中壓供電技術(shù)在長大和連續(xù)公路隧道中的應(yīng)用、通風(fēng)與照明供配電綜合布線系統(tǒng)、連續(xù)隧道變電站的合理布局、適應(yīng)交通量增長的供配電系統(tǒng)分步實施方法、節(jié)能型供電線纜和設(shè)備對比。

2、變壓器大馬拉小車現(xiàn)象突出,大多數(shù)投入運營的隧道變壓器負載率都在10%—30%左右,造成極大的資源浪費,也造成隧道運營期間費用偏高。

3、低壓配電電纜初期投資和運營費用高

隧道內(nèi)低壓配電電纜為長距離供電,設(shè)計者一般都按電壓降進行電纜截面的選擇,由此確定的電纜截面遠遠超過按經(jīng)濟電流選擇的電纜截面。目前,供配電設(shè)計人員受隧道內(nèi)環(huán)境污染嚴重思想的影響, 通常將隧道變電所設(shè)置在隧道洞口外,因此造成隧道內(nèi)低壓配電電纜更加長距離供電。隨著電纜主要源材料鋼材價格不斷上漲,電纜價格高居不下,沒有從設(shè)計上考慮低壓電纜工程造價 同時,設(shè)計者往往忽略了長距離供電的低壓配電電纜有功和無功損耗都是比較大的,造成長期運營的浪費。

4、系統(tǒng)方案差異大

由于設(shè)計者對隧道用電負荷的重要程度理解不同, 國內(nèi)沒有相關(guān)設(shè)計手冊, 因此不同設(shè)計者的隧道供電系統(tǒng)方案差異很大,不便于隧道運營管理和維護。

四.我國隧道供配電及照明系統(tǒng)中存在的問題

1、現(xiàn)有隧道照明控制營運中節(jié)能與安全的矛盾突出

一些地方的營運者為了節(jié)省隧道供配電及照明系統(tǒng)所產(chǎn)生的電費,往往在設(shè)計的時候都主動的避免采用自動控制,而是較多的采用手動控制的方式進行工作,制定了專門的開關(guān)隧道燈的時間,再由人工在規(guī)定的時間里進行控制。但是

由于隧道一天里弄內(nèi)外的亮度變化很大,人工根本無法進行精確的掌控。司機也

很有可能在規(guī)定熄燈的時間里通過隧道,所以很有可能造成事故。有過隧道駕駛經(jīng)驗的人都知道,在車子通過隧道的全程中,由于洞內(nèi)洞外亮度的不一致,在剛進入隧道和要出隧道口的時候,人的視覺會出現(xiàn)短暫的“黑洞效應(yīng)”,短時間內(nèi)無法看清楚前方的路況,這時候如果前后方有車輛或者駕駛不當(dāng)?shù)臅r候,就非??赡艹霈F(xiàn)事故。這對隧道的照明就提出了非常高的要求。但是如何在提供較好的照明前提下又適當(dāng)?shù)墓?jié)省電能,這已經(jīng)成為一個非常尖銳的矛盾。

2、現(xiàn)有隧道照明控制模式設(shè)計,在實際運行中存在很大的電能浪費

目前,隧道照明設(shè)計者依據(jù)規(guī)范通常把隧道分為入口段、過渡段、中間段和出口段等四個段來設(shè)計照明,其中過渡段有兩個,分別設(shè)計在中間段前后。各段的長度和照度是從全年行車安全要求出發(fā),對洞內(nèi)最大照度的設(shè)計是以全年洞外最大亮度和最高行車時速來確定隧道內(nèi)各段的燈具功率和燈具分布密度。能夠?qū)崿F(xiàn)照明自動控制的非常有限,通常因線路布線回路的限制,只能做到2、3級人工或自動控制,對于如天氣、車速、車流量等參數(shù)只是在設(shè)計階段給予以最大值考慮,最終各段照明的長度和照度也始終是處于最大值狀態(tài)。對于天氣、車速、車流量等時變參數(shù)無法從宏觀上對整個隧道的照明進行自適應(yīng)方式調(diào)制。因此,目前這種傳統(tǒng)設(shè)計與使用的隧道照明系統(tǒng)存在著大量電能浪費問題。

3、隧道供配電系統(tǒng)設(shè)計中存在著諸多不合理因素

目前國內(nèi)隧道普遍采用的供電系統(tǒng)模式為:在隧道洞口設(shè)置10/0.4KV變電所,采用0.4KV低壓線路向隧道內(nèi)的用電設(shè)施供電。采用這種方式供電的隧道,供電距離有時會達到1000米甚至更遠。設(shè)計中變壓器容量的選擇一般參考的是隧道內(nèi)和隧道洞口所有負荷的容量總和,并考慮一定的預(yù)留。隧道尤其是長隧道中具有相當(dāng)數(shù)量的射流風(fēng)機,但大多數(shù)時間這些大功率設(shè)備未處于運轉(zhuǎn)狀態(tài),隧道的照明燈具出于節(jié)電考慮在實際運營中也通常沒有全部打開,隧道的用電負荷還包括洞口消防水池的水泵等不常使用的大功率設(shè)備。上述變壓器的選型原則和實際運營情況的矛盾就造成變壓器長期處于低負荷的不經(jīng)濟運行狀態(tài)之下,造成了大量的變壓器鐵磁損耗。更有甚者在個別項目中由于變壓器容量選取的過大,其損耗的百分比已經(jīng)接近實際用電的負荷。

4、大量高能耗燈具的使用

目前,我國國內(nèi)的隧道供配電及照明系統(tǒng)中主要以高壓鈉燈作為光源,它的特點是配置了電感型鎮(zhèn)流器,它對電壓的要求比較高,使用壽命短,功耗高,并且色性較差,燈具本身無法對光強進行控制。所以,為了保證隧道的照明,一般要配置多條照明回路,導(dǎo)致了電纜數(shù)量的增加,提高了故障率,增加了施工過程的難度和施工時間。

解決高能耗問題的幾種方法

1、優(yōu)化變壓器的配置方案。

變壓器運行損耗的大小很大程度上取決于容量及同樣負荷容量下變壓器個數(shù)的選擇。在供配電的設(shè)計中應(yīng)當(dāng)將各種負荷按照其運行的時間規(guī)律來進行分類,并為不同的負荷單獨配備壓器

2、采用新型的節(jié)能型燈具。

研發(fā)能替代高壓鈉燈的綠色節(jié)能型燈具是目前隧道節(jié)能的一個突破口。

電磁感應(yīng)燈:

白光LED燈:L印光源具有節(jié)約能源、污染少、光指向性好、壽命長(約為8萬小時)、低電壓、反應(yīng)快的特點,在隧道誘導(dǎo)系統(tǒng)方面的應(yīng)用有很大研討空間。

電磁感應(yīng)燈:它是一種全新的照明光源,具有高光效、高顯色、環(huán)保、長壽命、節(jié)能、安全、性能穩(wěn)定的特點和優(yōu)勢,一般用在景觀照明燈、室內(nèi)照明,尤其當(dāng)被照物有較高的顯色要求時,能充分發(fā)揮它的優(yōu)勢。同時,它的光不刺眼、無污染、無眩光,這對隧道供配電及照明系統(tǒng)有著重要的意義。

3、優(yōu)化燈具布設(shè)的設(shè)計

在隧道供配電及照明系統(tǒng)的設(shè)計中,我們一般設(shè)計的時候,會在隧道的兩頭安裝較多的燈具,中間段的燈具安裝的較為少一些,但是由于不同隧道的長度和情況對照明的要求是不一樣的,我們在設(shè)計的時候就不能片面的按照我們的常規(guī)設(shè)計來,要具體的情況具體對待,充分考慮到車速、車流量、隧道長度、隧道亮度、洞外亮度等情況,優(yōu)化燈具布設(shè)的設(shè)計。

4、改進供配電系統(tǒng)的設(shè)計,更合理的進行設(shè)備選型。

中壓供電模式在長隧道和隧道群中應(yīng)用的推廣。改變以往在長隧道兩端洞口設(shè)置10/0.4KV變電所的設(shè)計模式,而采用10KV中壓進洞的供電方式。中壓供電是國外已廣泛應(yīng)用于道路機場、隧道等長距離照明供電的一項技術(shù)成熟、設(shè)備先進、系統(tǒng)配套的專用型供電設(shè)施。

結(jié)束語

對于隧道運營節(jié)能, 國內(nèi)業(yè)界還任重而道遠,無論是相關(guān)政府機構(gòu)、高速公路建設(shè)業(yè)主、管理部門,還是相關(guān)科研設(shè)計從業(yè)結(jié)構(gòu)與從業(yè)人員,都需要從人力、物力、財力各方面加大投入,在保證交通安全的前提下,為建設(shè)節(jié)約型社會作出應(yīng)有的貢獻。

參考文獻:

[1]高遠望 隧道供配電及照明系統(tǒng)中節(jié)能技術(shù)綜合應(yīng)用的探索 [會議論文]2006 - 第八屆中國高速公路信息化管理及技術(shù)研討會

[2]朱斌 中壓電能傳輸技術(shù)在公路隧道中的應(yīng)用 [學(xué)位論文] 2007 - 長安大學(xué):交通信息工程及控制

供配電設(shè)計論文范文3

供電設(shè)計的原則

關(guān)鍵詞:供配電;負荷;火災(zāi);設(shè)計

一、電力負荷等級劃分及供電要求

(一)負荷分級

由于不可能對所有的用電單位和用電設(shè)備都采取相同的供電措施,所以供配電設(shè)計應(yīng)首先對用電單位和用電設(shè)備進行負荷分級。負荷分級應(yīng)根據(jù)用電單位(即電能用戶)和用電設(shè)備的規(guī)模、功能、性質(zhì)及其在政治、經(jīng)濟上的重要性進行確定。國際上普遍的做法是將負荷按應(yīng)急電源自動切換的允許中斷供電時間劃分為0s、小于0.15s、0.5s、15s和大于15s五個級別,而我國則是沿用前蘇聯(lián)的做法,按用電單位或用電設(shè)備突然中斷供電所導(dǎo)致后果的危險性和嚴重程度分為一、二、三級。另外人防工程負荷分級中用電負荷應(yīng)分別按平時和戰(zhàn)時用電負荷的重要性、供電連續(xù)性及中斷供電后可能造成的損失或影響程度分為一級負荷、二級負荷和三級負荷。平時用電負荷分級,應(yīng)同時滿足《人民防空地下室設(shè)計規(guī)范》和地面同類建筑國家現(xiàn)行有關(guān)標(biāo)準之規(guī)定。由于各行業(yè)的各類負荷很多,通用性規(guī)范只能對負荷分級作原則性規(guī)定,具體行業(yè)中負荷等級詳細的劃分需在相應(yīng)行業(yè)標(biāo)準中規(guī)定。常用的重要用電負荷分級(含人防戰(zhàn)時負荷分級)。

(二)供電要求

1.供配電系統(tǒng)力求簡單可靠,操作安全,運行靈活,檢修方便。正常工作電源與柴油發(fā)電機組的應(yīng)急電源應(yīng)自成系統(tǒng)、獨立配電,事故時應(yīng)能自動切換。消防用電等一類負荷在火災(zāi)情況下,由應(yīng)急電源保證連續(xù)供電,二類負荷應(yīng)保證兩回路切換供電.低壓配電級數(shù)不宜過多。如從變電所的低壓配電裝置算起,則配電級數(shù)一般不多于四級,重要負荷不超過一級??偱潆婇L度一般不宜超過200m,每路干線的負荷計算電流一般不宜大于200A.

2.變配電設(shè)備的布置應(yīng)便于安裝和維護。高層民用建筑的地下層通常有兩層,宜將總配電室(變電所)設(shè)在地下一層。柴油發(fā)電機宜用風(fēng)冷式機組,且機房最好設(shè)置在地下一層;一是便于通風(fēng)冷卻;二是可與變配電室中的設(shè)備共用運輸通道。為防火的需要,不宜設(shè)置可燃油浸的電力變壓器、高壓電容器和多油開關(guān),而應(yīng)采用干式變壓器與高壓真空開關(guān).各樓層配電室宜設(shè)在電氣豎井內(nèi),一般情況下配電箱與電纜分裝在豎井內(nèi)的不同側(cè)面.

3.供配電系統(tǒng)的網(wǎng)絡(luò)設(shè)計應(yīng)合理。民用建筑中的低壓配電網(wǎng)絡(luò)多采用混合式配電系統(tǒng)。其中地下室與裙樓部分采用放射式配電,主體部分采用樹干式配電。根據(jù)負荷大小和樓層層數(shù)的多少,決定選用分區(qū)樹干式還是母線樹干式配電系統(tǒng)。樹千式的配電形式一般為電纜或插接式絕緣母線槽沿垂直的電氣豎井內(nèi)敷設(shè).

4.要適應(yīng)建筑的發(fā)展。隨著經(jīng)濟的發(fā)展,新設(shè)備、新材料、新功能等不斷增多,因此供配電系統(tǒng)應(yīng)適應(yīng)高層民用建筑不斷發(fā)展的需要。供配電系統(tǒng)的設(shè)計,是建筑電氣設(shè)計的重要組成部分,合理與否會影響整個建筑使用功能及安全。

二、合理選擇供電設(shè)備

(一)高、低壓設(shè)備的選擇

高壓設(shè)備選擇的一般要求必須滿足一次電路正常條件下和短路故障條件下的工作要求,同時設(shè)備應(yīng)工作安全可靠,運行方便,投資經(jīng)濟合理。高壓刀開關(guān)柜的選擇要滿足變電所一次電路圖的要求,并各方案經(jīng)濟比較優(yōu)選出開關(guān)柜型號及一次結(jié)線方案編號。同時確定其中所有一次設(shè)備的型號規(guī)格。

(二)導(dǎo)線、電纜的選擇

為了保證供電系統(tǒng)安全、可靠、優(yōu)質(zhì)、經(jīng)濟地運行,進行導(dǎo)線和電纜截面選擇時必須滿足供電所需的發(fā)熱條件、電壓損耗條件、經(jīng)濟電流密度和導(dǎo)線電纜的機械強度等各方面的要求,對于絕緣導(dǎo)線和電纜,還應(yīng)滿足工作電壓的要求。根據(jù)設(shè)計經(jīng)驗,一般10KV及以下高壓線路及低壓動力線路,通常先按發(fā)熱條件來選擇截面.再校驗電壓損耗和機械強度。低壓照明線路,因其對電壓水平要求較高,因此通常先按允許電壓損耗進行選擇,再校驗發(fā)熱條件和機械強度。對長距離大電流及35KV以上的高壓線路。則可先按經(jīng)濟電流密度確定經(jīng)濟截面,再校驗其它條件。

(三)配電所高壓開關(guān)柜的選擇

高壓開關(guān)柜是按一定的線路方案將有關(guān)一、二次設(shè)備組裝而成的一種高壓成套配電裝置,在發(fā)電廠和變配電所中作為控制和保護發(fā)電機、變壓器和高壓線路之用,也可作為大型高壓開關(guān)設(shè)備、保護電器、監(jiān)視儀表和母線、絕緣子等。

三、電氣照明設(shè)計

人眼對外界環(huán)境明亮差異的知覺,取決于外界景物的亮度。但是,規(guī)定適當(dāng)?shù)牧炼人较喈?dāng)復(fù)雜,因為它涉及各種物體不同的反射特性。所以,在實踐中是以照度水平作為照明的數(shù)量指標(biāo)。設(shè)計中應(yīng)根據(jù)不同場所的特點和作業(yè)對視覺的要求確定照度,并應(yīng)按照GB50034-2004《建筑照明設(shè)計標(biāo)準》的相關(guān)規(guī)定執(zhí)行。

照度標(biāo)準值分級應(yīng)為0.5、1、3、5、10、15、20、30、50、75、100、150、200、300、500、750、1000、1500、2000、3000、5000lx。標(biāo)準值是以維持平均照度作為照度標(biāo)準值。

四、火災(zāi)自動報警及聯(lián)動系統(tǒng)

按國標(biāo)GB50116-98《火災(zāi)自動報警系統(tǒng)設(shè)計規(guī)范》要求,建筑物火災(zāi)自動報警系統(tǒng)的保護共分三級,即特級、一級、二級。

建筑高度為24米及以下的建筑物消防系統(tǒng)設(shè)計按國標(biāo)《建筑設(shè)計防火規(guī)范》執(zhí)行,24~100米高的建筑物按國標(biāo)《高層民用建筑設(shè)計防火規(guī)范》執(zhí)行。國標(biāo)是約束業(yè)主、設(shè)計單位、施工單位和驗收單位強制性技術(shù)規(guī)定。超高層建筑尚無相應(yīng)國標(biāo),在實際設(shè)計中可參照有關(guān)國標(biāo)及國際標(biāo)準,并依據(jù)當(dāng)?shù)叵乐鞴懿块T意見,本著安全第一的精神,仔細周詳?shù)耐瓿稍O(shè)計工作。

民用建筑的火災(zāi)自動報警及聯(lián)動系統(tǒng)包括:火災(zāi)探測器、消防報警控制器、消防通風(fēng)系統(tǒng)和自動灑水滅火系統(tǒng)等四個部分,實現(xiàn)報警滅火自動化。

(一)關(guān)于消防自動報警和自動滅火系統(tǒng)的設(shè)計應(yīng)從以下幾個方面入手:

報警探測器安裝、報警手段、自動滅火方面、手動滅火方面、通訊設(shè)備、擋煙垂壁的設(shè)置以及避難層的消防安排等。

(二)其他重要的防火手段,在高層建筑中包括:

防火閥:為了防止煙火沿風(fēng)管蔓延而設(shè)置,因而一般在通風(fēng)機房外側(cè)裝設(shè)。通風(fēng)風(fēng)管穿越電氣設(shè)備間時在電氣設(shè)備間過墻處的風(fēng)管上的墻內(nèi)、墻外要各設(shè)一個防火閥,使設(shè)備間的煙火不能外傳,也避免外面的煙火導(dǎo)入設(shè)備間。

平時防火閥處于開啟狀態(tài),火災(zāi)時當(dāng)風(fēng)管中溫度達到70℃,防火閥中的易熔片熔斷,防火閥在彈簧的作用下迅速關(guān)閉,阻斷管道。滅火結(jié)束后,防火閥可手動復(fù)位。

排煙閥:設(shè)于排煙風(fēng)機的排煙管道上,多位于出戶風(fēng)口附近。排煙閥平時關(guān)閉?;馂?zāi)之初打開,隨之排煙風(fēng)機聯(lián)動啟動排煙,當(dāng)煙氣溫度達到280℃時,排煙閥自動關(guān)閉。

正壓送風(fēng)系統(tǒng):正壓風(fēng)機一般處于屋頂,與各層的電動風(fēng)口聯(lián)動?;馂?zāi)初期打開送風(fēng)口,啟動正壓送風(fēng)機,使樓梯間、電梯廳等疏散區(qū)域處于較高的風(fēng)壓狀態(tài)。阻止煙氣進入。

火災(zāi)報警系統(tǒng)的有效起作用有賴于噴淋系統(tǒng)的可靠工作。當(dāng)室溫升到68℃時,噴淋頭的玻璃球會爆破噴灑,此為滅火直接有力的措施,為了監(jiān)測該系統(tǒng)的正常工作,噴淋系統(tǒng)設(shè)水流指示器,濕式報警閥、噴淋閥等探測信號裝置,以及時反映水噴淋系統(tǒng)的工作狀態(tài)。

火災(zāi)自動報警及聯(lián)動系統(tǒng)設(shè)計不僅要深刻理解消防規(guī)范的相關(guān)規(guī)定、條文,更要與水暖專業(yè)密切配合,了解各專業(yè)消防對電氣的要求,使設(shè)計做到合理、經(jīng)濟、適用。

五、結(jié)語

以上論文介紹的概括,結(jié)合部分規(guī)范闡述一下該系統(tǒng)。就電負荷、消防方面,合理性,安全性作了闡述。建筑工程的電氣設(shè)計中,需要講究設(shè)計的可操作性、延續(xù)性、系統(tǒng)性和整體協(xié)調(diào)性。所以在建筑工程中尤為重要。

參考文獻:

[1]《民用建筑電氣設(shè)計規(guī)范應(yīng)用圖解》 機械工業(yè)出版社

供配電設(shè)計論文范文4

強電部分主要內(nèi)容包括:本論文由應(yīng)屆畢業(yè)生網(wǎng)yjbys.com/整理提供配電系統(tǒng)、照明系統(tǒng)及防雷接地系統(tǒng)的設(shè)計,其中包括負荷計算等。

弱電部分主要內(nèi)容包括:有線電視、公共廣播系統(tǒng)及綜合布線系統(tǒng)的設(shè)計。

消防部分主要報警系統(tǒng)、聯(lián)動系統(tǒng)的設(shè)計等。

本次設(shè)計完成圖紙共18幅,繪圖采用AUTOCAD軟件繪制。

本電氣設(shè)計為畢業(yè)設(shè)計,其目的是通過設(shè)計實踐,綜合運用所學(xué)知識,理論聯(lián)系實際,鍛煉獨立分析和解決建筑電氣設(shè)計問題的能力,為未來的工作奠定堅實的基礎(chǔ)。

Abstract :This thesis mainly explains the electrical design basis ,principle, methods and the conclusion of the design choice in each system in the design of certain office building. The thesis includes six Chapters. previous four Chapters are mostly about the design of the forceful electric power Part ;Chapter 5 and 6 are mostly about the design of the light current and fire-fighting.

The part of the forceful electric power mainly including: the distribution system of the low voltage, lighting system and rounding for lightening systematical compose ,among others include load calculation, illumination calculation .

The part of the light current mainly including: CATV, Public Broadcasting System, Closed Circuit Monitoring TV and Premises Distribution System and so on.

The part of the fire-fighting mainly including:the design of the warning system and linked system etc.

The design adds up to 34 electric charts. Including 17 graphics for the forceful electric power parts ,9 graphics for the light current parts and 7 graphics for the fire-fighting parts. All drawn by AUTOCAD.

This electrical design of the office building is a graduation design,The purpose of this design is to give us a chance of synthetical usage of the knowledge we have learned. Besides, it can train our ability to analyze and solve practical problems in Construct electricity in dependently so that the theory is connected with practice and a solid base is made in favor of future work.

目 錄

一.緒論 6

1.1.建筑電氣概況 6 1.3設(shè)計內(nèi)容 6

二.配電系統(tǒng)設(shè)計 9

2.1負荷分級 9

2.1.1一級負荷 9 2.1.3三級負荷 9

2.2負荷的供電要求 9

2.2.1一級負荷的供電要求 9

2.2.2二級負荷的供電要求 9

2.2.3三級負荷的供電要求 10

2.3本工程的負荷分級及供電要求 10

2.3.1本工程的負荷分級 10

2.3.2本工程負荷的供電要求 10

2.4負荷計算 10

2.4.1負荷計算的內(nèi)容 10

2.4.2負荷計算的方法 10

2.4.3負荷計算的公式 11

2.4.4負荷計算表 11

2.5變(配)電所所址選擇,結(jié)構(gòu)型式 11

2.5.1變(配)電所所址選擇 11

2.5.2變(配)電所結(jié)構(gòu)型式 12

2.6變壓器類型,臺數(shù),容量選擇 12 2.6.2變壓器臺數(shù)選擇 12

2.6.3變壓器容量選擇 12

2.7配電方式 12 2.7.2低壓配電方式 12

2.8電纜選擇及敷設(shè) 13

2.8.1電纜選擇的原則 13

2.8.2電纜選擇的結(jié)果 13

三.照明系統(tǒng)設(shè)計 14

3.1總則 14

3.2照明光源選擇 14

3.3照明燈具選擇 14

3.4照度和照明方式選擇 15

3.5一般照明 15

3.6應(yīng)急照明 16

3.7照度計算 17

四.建筑物防雷,接地系統(tǒng)設(shè)計 18

4.1建筑物的防雷分類 19

4.2建筑物的防雷措施 20

4.3本建筑的防雷系統(tǒng) 22

供配電設(shè)計論文范文5

1、產(chǎn)生與技術(shù)標(biāo)準分支電纜是在普通塑力纜基礎(chǔ)上發(fā)展而來。

由于現(xiàn)代文明的發(fā)展,都市的高層建筑越來越普及,在高層建筑配電系統(tǒng)電氣設(shè)計中,供電可*性、工程經(jīng)濟性和施工便利性越來越重要,采用普通電力電纜供電,三者的矛盾總難完全統(tǒng)一,只能根據(jù)不同工程而有所側(cè)重。按傳統(tǒng)方法,在樓層配電設(shè)計中,通常采用的辦法有三種:

(1)放射式,由地下配電間分別對各個樓層引電纜直接供電,卻需要大量的電纜、橋架和較大的電纜井,造價高,經(jīng)濟性最差。

(2)鏈接法,由配電間引出電纜至底層配電箱,再由底層逐層向上鏈接供電,此法經(jīng)濟性最佳,但由于層數(shù)越多,安全系數(shù)越低(安全系數(shù)是逐級相乘)。

(3)分區(qū)樹干式,把一座高層建筑劃分成n個單元區(qū),每個單元采用電纜接從配電室供電,然后再分配至單元區(qū)內(nèi)各個樓層。經(jīng)濟性都比較好,經(jīng)常被采用。

(4)干線電纜分支法,從配電室引出一根(或數(shù)根)主干電纜,每個樓層在干線電纜上供頭分支,此法經(jīng)濟性最好,但施工卻是最麻煩的,更麻煩的是在主電纜上做樓層分支頭時,受電纜的結(jié)構(gòu)和現(xiàn)場施工條件以及人員素質(zhì)的影響,接頭質(zhì)量參差不齊,但這種方法卻促使人們想到把接頭與電纜一同制造,由此誕生了新一代的建筑配電電纜——分支電纜。

分支電纜是把經(jīng)過專門工藝處理的單芯電力電纜作為建筑主干電纜,根據(jù)各具體建筑的結(jié)構(gòu)特點和尺寸量體裁衣,預(yù)先把分支接頭與分支線、主干電纜一同設(shè)計制造。是把上面第(4)種方法中現(xiàn)場施工和管理的工作由專業(yè)制造廠完成,而且工藝一致性也帶來了質(zhì)量一致。

分支電纜較早出現(xiàn)于英國和日本,在技術(shù)標(biāo)準方面,1980年,日本電線工業(yè)協(xié)會頒布了第一部行業(yè)性標(biāo)準JCS376(1980),隨著技術(shù)的發(fā)展與進步,在1992年對該標(biāo)準進行了修訂,放寬了對產(chǎn)品結(jié)構(gòu)材料方面的要求,提高了成品技術(shù)指標(biāo),目前,國內(nèi)正規(guī)的分支電纜生產(chǎn)廠的產(chǎn)品標(biāo)準主要是以該標(biāo)準為基礎(chǔ)。

2、結(jié)構(gòu)分支電纜在結(jié)構(gòu)上,分為單芯型和多芯絞合型兩種,每根單芯分支電纜又可分為三部分:

(1)主干電纜;(2)支線電纜;(3)分支連接體。

目前,因單芯型分支電纜結(jié)構(gòu)簡單,本論文由

型分支電纜實質(zhì)上是多個單芯電纜的絞合體,而不是傳統(tǒng)概念多芯電纜的結(jié)構(gòu),多芯型分支電纜的每項導(dǎo)體外面都有單獨的絕緣和護套,每根線芯有獨立的分支連接體。多芯型分支電纜具備一般多芯電纜的運行性能,國內(nèi)只有為數(shù)極少的大型綜合性電纜廠才具備生產(chǎn)能力,目前也已在推廣應(yīng)用中。

3、性能分支電纜是一種新型的電力配送電纜,其關(guān)鍵性能有兩項:首先,一根具備良好品質(zhì)的分支電纜,必須是性能優(yōu)良的電力電纜,對于國內(nèi)產(chǎn)品,其導(dǎo)體性能、絕緣性能、材料的機械物理性能均應(yīng)符合GB12706-91標(biāo)準——電纜的性能是分支電纜產(chǎn)品的基礎(chǔ)指標(biāo)。

第二,分支連接體的性能至關(guān)重要,這是分支電纜的關(guān)鍵性能。分支連接體把干線電纜與支線電纜的導(dǎo)體連為一體,并作絕緣防潮處理。從外觀上看,無法知道內(nèi)部接頭質(zhì)量,有兩項重要的試驗?zāi)軌驒z測接頭性能,即機械拉力試驗和電熱循環(huán)試驗。對機械拉力試驗而言,分支連接體(含干線與支線導(dǎo)體)的拉斷力應(yīng)保持在連接前的80%以上,對電熱循環(huán)試驗而言,在125次一定時間間隔的額定載荷與空載循環(huán)后,分支連接體的溫度不得大于電纜表面溫度的8℃。決定分支連接體的機械與電氣性能的關(guān)鍵在于分支連接體的材料和工藝。對廣大用戶而言,應(yīng)充分關(guān)心分支電纜的電纜質(zhì)量、接頭的材料選擇和生產(chǎn)工藝工裝。

我們講,分支電纜更適合于現(xiàn)代建筑的配電系統(tǒng),為什么?要分析這個問題,我們必須首先弄清楚相關(guān)電氣設(shè)計規(guī)范中對配電線路的要求。

二、相關(guān)規(guī)范對建筑電氣系統(tǒng)中配電線路的設(shè)計要求

1、建筑電氣相關(guān)的設(shè)計規(guī)范目前與建筑電氣低壓配電系統(tǒng)設(shè)計有關(guān)的規(guī)范主要有:

(1)GB50052-1995供配電系統(tǒng)設(shè)計規(guī)范

(2)GB50054-1995低壓配電設(shè)計規(guī)范

(3)JGJ/T16-92民用建筑電氣設(shè)計規(guī)范

(4)GBJ16-87建筑設(shè)計防火規(guī)范(1997年版本)

(5)GB50045-1995高層民用建筑設(shè)計防火規(guī)范其中:《供配電系統(tǒng)設(shè)計規(guī)范》和《低壓配電設(shè)計規(guī)范》是兩項基礎(chǔ)規(guī)范,主要內(nèi)容參照采用了IEC標(biāo)準。本論文由

致,但由于這是一個建筑行業(yè)的專業(yè)標(biāo)準,建筑相關(guān)的部分規(guī)定更具體,如供電系統(tǒng)的負荷簡等級,除規(guī)定分級原則外,更規(guī)定了各類具體建筑名稱的負荷級別。

由于上述規(guī)范在頒布實施時,分支電纜產(chǎn)品在國內(nèi)還沒有應(yīng)用先例,因此在規(guī)范中并未提及分支電纜,但在眾多條款中體現(xiàn)了設(shè)計指導(dǎo)方向,總的說來,有三種觀點:

1、關(guān)于配電級數(shù)——越少越好;

2、關(guān)于配電方式,從高到低依次為放射式>樹干式>分區(qū)樹干式>鏈接式;

3、關(guān)于安裝敷設(shè)方式,應(yīng)與環(huán)境、建筑特征、機電應(yīng)力等多種因素相適應(yīng)。

(一

)、關(guān)于配電級數(shù):對配電級數(shù)而言,GB50052-95第3.07條規(guī)定:供電系統(tǒng)應(yīng)簡單可*,同一電壓供電系統(tǒng)的變配電級數(shù)不宜多于兩級,JGJ/T16-92《民用建筑電氣設(shè)計規(guī)范》中8.14條規(guī)定:“自變壓器一次側(cè)至用設(shè)備之間的低壓配電級數(shù)不宜超過三級,但對非重要負荷供電時,可超過三級?!鄙鲜鲆?guī)范體現(xiàn)了一個要領(lǐng),那就是配電級數(shù)越少越好,越少可*性越高,技術(shù)越先進。

(二)、關(guān)于配電方式,GB50052-95中第6.02、6.03、6.04、6.05條中提出:“在正常環(huán)境的車間或建筑物內(nèi),當(dāng)大部分用電設(shè)備為中小容量,但無特殊要求時,宜采用樹干式配電”,“當(dāng)用電設(shè)備為大容量,或負荷性質(zhì)重要,或在有特殊要求的車間、建筑物內(nèi),宜采用放射式配電”,“當(dāng)部分用電設(shè)備離供電點較遠,而彼此相距很近、容量很少的用電設(shè)備,可采用鏈式配電,但每一回路環(huán)鏈設(shè)備不超過5臺,其總?cè)萘坎灰顺^10kW”:“在高層建筑物內(nèi),當(dāng)向樓層各配電點供電時,宜采用分區(qū)樹干式配電,但部分較大容量的集中負荷或重要負荷,應(yīng)從低壓配電室以放射式配電”。

(三)、JGJ/T16-92《民用建筑電氣設(shè)計規(guī)范》中對配電方式有更為詳細的規(guī)定,如:“8.2.15居住小區(qū)的高層建筑,宜采用放射式配電”“8.2.2.4除多層民用住宅外的其他民用建筑,對于較大的集中負荷或較重要的負荷應(yīng)從配電室以放射式配電;對于向多層配電間或配電箱配電,宜采用樹干式和分區(qū)樹干式的方式”“由層間配電間或?qū)优潆娤渲粮鞣峙潆娤涞呐潆?,宜采用放射式與樹干式結(jié)合的方式”,“8.2.3.2對于容量較大的集中負荷或重要負荷,宜從配電室以放射式配電對各層配電間的配電宜采用下列方式之一:

(1)工作電源采用分區(qū)樹干式,本論文由

(2)工作電源和多用電源都采用由首層到頂層垂直干線方式。

(3)工作電源采用分區(qū)樹干式,多用電源取自應(yīng)急照明等電源干線。

上述規(guī)定,是限于制定規(guī)范時,分支電纜尚未在國內(nèi)推廣應(yīng)用,供電線路主要依賴普通電力電纜和母線。筆者認為,在應(yīng)用分支電纜配電后,上述規(guī)定應(yīng)該可以簡化。放射式高于樹干式,又高于鏈接式的觀點。

(四)、關(guān)于電纜和母線安裝敷設(shè)方式。

GB50054-94中5.5.1、JGJ/T16-92中9.12.1都規(guī)定“封閉母線宜用于干燥和無腐蝕性的屋內(nèi)場所?!?/p>

GB50054-94中5.7.2、JGJ/T16-92中4.13.5規(guī)定“豎井垂直布線時應(yīng)考慮下列因素:……。垂直干線與分支線的連接方法?!?/p>

GB50054-94中5.7.3豎井內(nèi)垂直布線采用大容量單芯電纜大容量線線作干線時,應(yīng)滿足下列條件:

1、載流量要留有一定的裕度;本論文由

GBJ16-87《建筑設(shè)計防火規(guī)范》中10.1.4規(guī)定:“消防用電設(shè)備的配電線路應(yīng)穿管保護。當(dāng)暗敷時應(yīng)敷時應(yīng)敷設(shè)在非燃燒體結(jié)構(gòu)內(nèi),其保護層厚度不應(yīng)小于3cm,明敷時必須穿金屬管,并采取防火措施。采用絕緣和護套為非延續(xù)燃性材料的電纜時,可不采取穿金屬管保護,但應(yīng)敷設(shè)在電纜井溝內(nèi)。

GB50045-95《高層民用建筑設(shè)計防火規(guī)范》中對消防電源及其配電,9.1.4條也規(guī)定了相同內(nèi)容。

上述規(guī)范說明:電纜配電比母線具有更好的環(huán)境適應(yīng)性,安裝敷設(shè)更便利。

在熟悉電氣規(guī)范的相關(guān)規(guī)定后,讓我們來分析分支電纜配電方法與規(guī)范的符合性與技術(shù)先進性.

三、分支電纜配電的技術(shù)先進性

1、分支電纜的配電方式分支電纜配電系統(tǒng)一般如圖所示,在一個n層的大樓中,垂直豎井干線和各樓層供電由一根整預(yù)制的分支電纜完成,PG是總配電柜,PX是樓層配電箱,ZJX是轉(zhuǎn)接箱,當(dāng)PG與ZJX之間距離不遠時,(滿足載流量與起動運行壓降要求)一般不予選用,這樣可減少一個連接點,節(jié)約投資。

2、分支電纜配電的技術(shù)先進性從上述配電系統(tǒng)的分析中,可以知道分支電纜可以使樓層配電簡化成二級配電,每個樓層都可以達到最簡單的二級配電,符合規(guī)范中配電級數(shù)越少越好的原則,這是先進性之一。

分支電纜配電系統(tǒng)的實質(zhì)是一種放射式配電系統(tǒng),適用于各種重要場合甚至是特別重要場合的配電,這是先進性之二。

分支電纜是一種經(jīng)過預(yù)制的電力電纜,本論文由

在出廠時經(jīng)受過水中耐壓和絕緣電阻試驗,因此對環(huán)境要求低,能適用于潮濕、鹽霧酸堿等環(huán)境,而母線在規(guī)范中明確不能應(yīng)用于這些環(huán)境,比母線適用范圍廣。而且,其安裝方式簡便,施工工期短,工費低,符合規(guī)范中設(shè)計應(yīng)注重經(jīng)濟性的觀點,這是其技術(shù)先進性之三。

四、分支電纜配電設(shè)計的注意點

我們已分析:分支電纜配電系統(tǒng)的技術(shù)先進性,可以說分支電纜就是一種為現(xiàn)代建筑度身定做,量體裁衣的專業(yè)產(chǎn)品,具有最佳的適用性和技術(shù)經(jīng)濟性,但在工程設(shè)計中,需注意一點——那就是分支線的保護問題。對由于支線截面一般都有比干線小,因此,當(dāng)支線發(fā)生過載或短路時,干線保護系統(tǒng)一般不會對其發(fā)生作用,必須在支線配電箱中設(shè)置保護器,保護器與分支接頭問題不超過3m,如超過,分支線必須受敷設(shè)在不燃的管或槽中,且當(dāng)該段發(fā)生單相或兩相短路時,干線保護應(yīng)能夠斷開。對此,應(yīng)予以注意。

分支電纜作為一種從國外傳入的新型建筑配電電纜,

員認同并使用。本文旨在說明分支電纜配電與現(xiàn)有建筑電氣相關(guān)規(guī)范的一致性,并能更好地體現(xiàn)規(guī)范的指導(dǎo)思想。是一種能滿足現(xiàn)有規(guī)范的一種最先進、經(jīng)濟的配電方式。因水平所限,文中如有謬誤,敬請讀者指正。

供配電設(shè)計論文范文6

論文摘要:文章就電氣節(jié)能設(shè)計應(yīng)遵循的原則,從供配電系統(tǒng)設(shè)計、合理使用電動機、功率因數(shù)補償、諧波治理、照明節(jié)能、可再生能源利用、能源管理系統(tǒng)等方面,論述了建筑電氣節(jié)能的合理應(yīng)用。

隨著我國經(jīng)濟的持續(xù)快速增長,作為二次能源的電能供需矛盾日益突出。在積極倡導(dǎo)節(jié)能減排、發(fā)展低碳經(jīng)濟的今天,如何把節(jié)能措施貫穿于整個電氣設(shè)計過程則顯得尤為重要。下面結(jié)合工作實際,就建筑電氣設(shè)計的幾種節(jié)能措施談?wù)勔恍┛捶ā?/p>

1 電氣節(jié)能設(shè)計應(yīng)遵循的原則

電氣節(jié)能是建筑節(jié)能的重要組成部分,電氣設(shè)計人員在設(shè)計過程中,應(yīng)從適用性、安全性、可靠性及經(jīng)濟性多方面綜合考慮,通過合理的設(shè)計及運行方案減少不必要的能源損耗。

2 電氣節(jié)能設(shè)計包括以下幾方面內(nèi)容

2.1 合理設(shè)計供配電系統(tǒng)

根據(jù)用戶的重要性、負荷性質(zhì)、用電容量、工程特點、系統(tǒng)規(guī)模,合理設(shè)計供配電系統(tǒng),使系統(tǒng)在最佳狀態(tài)下運行。

2.1.1 根據(jù)用電負荷的容量及分布,使變、配電所靠近負荷中心,以縮短低壓供電半徑,降低線路損耗,減少電壓損失,滿足供電質(zhì)量要求。供配電線路長度不宜超過250m。

2.1.2 供配電系統(tǒng)應(yīng)簡單可靠,配電級數(shù)不宜過多,同一用戶內(nèi),高壓配電級數(shù)不宜多于兩級;變壓器二次側(cè)至用電設(shè)備間的低壓配電級數(shù)不宜超過三級,盡量減少電能損耗。由兩路進線供電的系統(tǒng),宜采用兩路電源同時運行的方式,以減少正常運行時的線路損耗。

2.1.3 合理選擇供電電壓。同等情況下,電壓越高,損耗越小。供電電壓等級的確定應(yīng)考慮技術(shù)經(jīng)濟合理性及電力公司的相關(guān)規(guī)定等因素。當(dāng)用電設(shè)備總?cè)萘吭?50kW及以上或變壓器容量在160kVA及以上時,宜以10(6)kV供電。對大型公共建筑的空調(diào)冷水機組,考慮節(jié)能因素,經(jīng)方案比較盡量采用10(6)kV冷水機組,但應(yīng)考慮大容量電動機啟動時對變壓器的影響。

2.1.4 合理選擇變壓器。電力變壓器應(yīng)當(dāng)選用10型及以上、非晶合金等節(jié)能環(huán)保、低損耗和低噪聲的變壓器。變壓器的長期工作負載率不宜大于0.85,在選擇變壓器容量和臺數(shù)時,應(yīng)靈活根據(jù)負荷變化情況,綜合考慮投資和年運行費用,對負荷合理分配,選取容量與電力負荷相適應(yīng)的變壓器,以實現(xiàn)其經(jīng)濟運行,減少由于輕載運行造成的不必要電能損耗。此外,降低變壓器的環(huán)境溫度、平衡三相負荷、合理選擇變壓器接線方式、季節(jié)性造成的負荷變化時靈活投切變壓器等也是降低能耗的有效途徑。

2.1.5 減少線路能量損耗。在滿足允許載流量、電壓損失、短路電流熱穩(wěn)定等技術(shù)指標(biāo)前提下,應(yīng)按經(jīng)濟電流密度合理校驗、選擇導(dǎo)線截面,從而達到降低電能損耗、減少投資和節(jié)約有色金屬的目的。

2.2 降低電動機電能損耗,提高電動機使用效率

2.2.1 根據(jù)負荷特性合理選擇高效率電動機,提高電動機運行的效率和功率因數(shù)。

2.2.2 功率較大的電動機可以采用變頻調(diào)速器(消防設(shè)備除外),可提高電機在輕載時的效率,達到節(jié)能的目的。

2.2.3 采用軟啟動器,使電機啟動平穩(wěn),保證電網(wǎng)電壓的波動在要求范圍內(nèi)。

2.3 合理提高供配電系統(tǒng)中的功率因數(shù)

設(shè)計中應(yīng)通過正確選擇電動機、變壓器的容量以及照明燈具啟動器,降低線路感抗,采用正確的電線、電纜敷設(shè)方式,提高用電單位的自然功率因數(shù)。當(dāng)自然功率因數(shù)偏低,達不到電網(wǎng)合理運行要求時,應(yīng)采用并聯(lián)電力電容器作為無功補償裝置。

2.4 諧波治理

隨著大量非線性負載的廣泛使用,產(chǎn)生的大量諧波電流注入電網(wǎng)中,使電壓波形產(chǎn)生畸變??赏ㄟ^選用D,yn11變壓器;設(shè)置濾波或隔離濾波裝置;合理選擇中性線截面;功率因數(shù)補償電容器組串聯(lián)消諧電抗器等措施抑制諧波,提高電能質(zhì)量。

2.5 照明節(jié)能

照明節(jié)能的基本原則是在保證不降低生產(chǎn)、作業(yè)視覺要求,不降低照明質(zhì)量的條件下,力求減少照明系統(tǒng)中光能的損失,最有效地使用照明用電。做好照明節(jié)能工作應(yīng)注意以下幾點:

2.5.1 根據(jù)視覺作業(yè)要求,應(yīng)根據(jù)《建筑照明設(shè)計標(biāo)準》確定合理的照明標(biāo)準,不同場所應(yīng)有目的地進行照明。由于我國幅員遼闊,各地區(qū)經(jīng)濟條件差別較大,民族習(xí)慣不同,因此還應(yīng)結(jié)合現(xiàn)場實際情況,在規(guī)范推薦的高、中、低值中確定合理的標(biāo)準,對標(biāo)準值的確定應(yīng)掌握適度,并合理利用局部照明。

2.5.2 充分利用自然光。照明的最佳光源是陽光。太陽光是免費的,不需電力,也不造成污染。在寫字樓里,如果在設(shè)計時能在大樓內(nèi)部引入自然光線,員工會情緒更好,效率更高。在醫(yī)院里,住在靠近窗戶附近的病人康復(fù)得更快?,F(xiàn)在有些窗戶可以對光譜進行選擇,引入日光的同時還可保持舒適。有一些創(chuàng)新的技術(shù)如側(cè)窗、天窗、光柵板和光線管道等,可將日光引入大樓內(nèi)部。在燈具布置時,將所控?zé)袅信c側(cè)窗平行,跟據(jù)日照強弱來進行燈具控制也是照明節(jié)能的有效手段。

2.5.3 合理選擇光源和燈具。應(yīng)在不同的使用場合,在滿足照明質(zhì)量的前提下,盡可能選擇高光效的光源。為充分利用光源發(fā)出的光通量,在燈具選用時應(yīng)注意選用配光合理、效率高、利用系數(shù)高的燈具,優(yōu)先選用開啟式直接照明燈具,并選擇電子鎮(zhèn)流器或節(jié)能型高功率因數(shù)電感鎮(zhèn)流器以提高功率因數(shù)。

2.5.4 采用合理的照明控制方式是實現(xiàn)舒適照明的有效手段,也是節(jié)能的有效措施。照明控制系統(tǒng)分兩大類:手動控制和自動控制。手動控制是指按照使用者的個人意愿來控制所屬區(qū)域的照度水平。在照明開關(guān)應(yīng)用中,我們應(yīng)注意:1 居住建筑有天然采光的樓梯間、走道的照明,除應(yīng)急照明外,宜采用節(jié)能自熄開關(guān)。2 每個照明開關(guān)所控光源數(shù)不宜太多。每個房間燈的開關(guān)數(shù)不宜少于2個(只設(shè)置一只光源的除外)。但手動控制最不利的一點是:當(dāng)人們意識到自然光線不足時會開燈,但當(dāng)天然光又恢復(fù)充足時沒有什么因素促使他們把燈關(guān)掉。而且工作結(jié)束后如果燈還開著,這將浪費大量的電能。與傳統(tǒng)的照明控制方式相比,近年來逐步發(fā)展起來的智能化照明控制系統(tǒng)體現(xiàn)出了強大的優(yōu)越性。目前智能照明控制系統(tǒng)多數(shù)采用現(xiàn)場總線技術(shù),借助各種不同的“預(yù)設(shè)置”控制方式和控制元件,對不同時間不同環(huán)境的光照度進行精確設(shè)置和合理管理,實現(xiàn)節(jié)能。只有當(dāng)必需時才把燈點亮或點到要求的亮度,利用最少的能源保證所要求的照度水平,節(jié)電效果十分明顯。

2.6 可再生能源利用

在條件允許的場所,合理利用太陽能、風(fēng)能等可再生資源,有利于節(jié)能減排、改善能源結(jié)構(gòu)、保護環(huán)境。

2.7 采用建筑設(shè)備自動化管理控制系統(tǒng)

自動控制、監(jiān)視和測量是自動化管理控制系統(tǒng)的三大要素。通過應(yīng)用信息通信、計算機網(wǎng)絡(luò)、自動化控制等智能化技術(shù),對建筑物內(nèi)采暖、通風(fēng)和空氣調(diào)節(jié)系統(tǒng)、給排水及熱水供應(yīng)系統(tǒng)、照明和其他各類用電設(shè)備系統(tǒng)的運行實施能效管理,確保各類設(shè)備系統(tǒng)運行穩(wěn)定、安全可靠,從而達到提高能效、降低能耗的目的。

3 結(jié)束語

電氣節(jié)能已成為電氣設(shè)計中的重中之重,作為建筑電氣設(shè)計人員,應(yīng)結(jié)合工程項目自身特點,精心設(shè)計、精心比較,采用切實可行的節(jié)能措施,把節(jié)能貫穿于電氣設(shè)計過程始終,真正把節(jié)能理念落到實處,促進資源節(jié)約型社會的更好建立。

參考文獻

主站蜘蛛池模板: 精品国产午夜理论片不卡精品| 无码h黄肉动漫在线观看| 久久久久成人精品无码| 久久av无码精品人妻出轨| 精品精品国产自在97香蕉| 天天躁日日躁狠狠躁性色av| 一本一本久久a久久精品综合麻豆| 99久久无码一区人妻a片蜜| 国产亚洲午夜高清国产拍精品| 久久精品国产亚洲av果冻传媒| 无码av岛国片在线播放| 无码一卡二卡三卡四卡| 麻豆国产人妻欲求不满| 国产96在线 | 欧美| 人人狠狠综合久久亚洲爱咲| 豆国产95在线 | 亚洲| 欧美高潮| 狠狠做深爱婷婷久久综合一区| 狠狠躁夜夜躁青青草原软件| 人妻熟妇乱又伦精品无码专区| 国产精品乱子乱xxxx| 国产仑乱无码内谢| 欧美午夜理伦三级在线观看| 中文字幕不卡av无码专线一本| 国产色婷婷亚洲99精品小说| 精品少妇ay一区二区三区| 中文字幕v亚洲日本在线电影| 少妇人妻偷人精品视蜜桃| 国产毛a片啊久久久久久保和丸| 国产内射老熟女aaaa∵| 国产婷婷综合在线视频| 狠狠躁天天躁无码中文字幕图| 精品久久无码中文字幕| 护士脱了内裤让我爽了一夜视频| 无码中文精品视视在线观看| 国产乱子伦一区二区三区四区五区| 久久精品欧美日韩精品| 久久久国产不卡一区二区| 欧美激情一区二区| 欧洲人与动牲交α欧美精品| 成人片黄网站色大片免费|